· Non-toxic
· Solvent-free therefore may be used in confined
areas
· High build
· No primer required on concrete or mild steel
· Easily cleaned surface
· Resistant to a wide range of chemicals
· Corrosion and abrasion resistant
Preparation
It is essential that adequate preparation is carried
out prior to the application of SpECcoat CRE200.
For concrete and steel surfaces, grit blasting is
recommended. Steel surfaces should be prepared to
bright metal Standard. The preparation should
ensure the removal of old coatings, laitance, curing
compounds, grease and oil.
Any imperfections or ‘blow holes’ should be filled
using SpECcoat BC.
Mixing
SpECcoat CRE200 is supplied in a two-component
kit consisting of a base component and a curing
agent.
The contents of the base
component must be stirred
thoroughly to disperse
settlement. The total
contents of the hardener
component should be
added to the base, taking
care to scrape the sides
of the can. Mechanical mixing must be used
incorporating a suitable mixing paddle attached
to a heavy duty, slow speed drill.
Mixing paddles are available from Speciality
Engineering Chemicals on request.
Application
The mixed material should be applied by suitable
brush.
The first coat should be applied to the substrate
using a scrubbing action to ensure a uniform build
of not less than 200µm. The first coat should be
allowed to dry for at least 8 hours at 20°C or 4
hours at 35°C. The maximum quoted overcoat
times should also be complied with (see above).
The second coat must be applied exactly as above
resulting in a film thickness of at least 200µm.
Should spray application be considered, contact our
Technical Department.
SpECcoat CRE200 is supplied in the pack sizes
given below with the following recommended
coverage rates:
SpECcoat CRE200
4.5 litres and 15 litres
@ 200 µm wft:
5.0m²/litre/coat
(minimum 2 coats)
N.B. Due to wastage factors and the varied nature
of substrates, actual coverage rates may be
significantly reduced.
Contact us for more info.